Appendix D of document 4150.2, marked 1/06, provides valuation and reporting protocols for appraisals supporting FHA-insured mortgages. It addresses minimum property requirements and standards, property inspections, repairs, environmental and safety hazards, comparable selection, appraiser responsibilities, certifications, and required exhibits. Detailed field-by-field instructions cover the Uniform Residential Appraisal Report (Fannie Mae Form 1004) and Manufactured Home Appraisal Report (Form 1004C), including property identification, neighborhood and site analysis, improvements, valuation approaches, and reconciliation. The supplied text ends partway through the manufactured-home reconciliation instructions.
Free preview text
The first 5 pages, shown as text so search engines and readers can find this document.
Page 1
4150.2
1/06
D- 1
APPENDIX D: VALUATION PROTOCOL
The appraisal process is the lender’s tool for determining if a property meets the minimum requirements
and eligibility standards for a FHA-insured mortgage. Underwriters bear primary responsibility for
determining eligibility; however, the appraiser is the on-site representative for the lender and provides
preliminary verification that the General Acceptability Criteria standards have been met.
FHA RESIDENTIAL APPRAISAL REQUIREMENTS
This section provides specific instructions for completing appraisal report forms.
The appraisal reporting form to be used will depend on the property type that is being appraised. The
appraiser must select the appropriate appraisal form for reporting an FHA appraisal from the following:
1. Uniform Residential Appraisal Report (Fannie Mae Form 1004 March 2005) – Required to report an
appraisal of a one-unit property or a one-unit property with an accessory unit.
2. Manufactured Home Appraisal Report (Fannie Mae Form 1004C March 2005) – Required to report
an appraisal of a one-unit manufactured home.
3. Individual Condominium Unit Appraisal Report (Fannie Mae Form 1073 March 2005) – Required to
report an appraisal of a unit in a condominium project or a condominium unit in a planned unit
development (PUD).
4. Small Residential Income Property Appraisal Report (Fannie Mae Form 1025) – Required to report
an appraisal of a two- to four-unit property.
An appraisal performed for HUD/FHA purposes requires that all sections of the appraisal form be
addressed. The appraiser must complete the form in a manner that clearly reflects the thoroughness of
the investigation and analysis of the appraisal findings. The conclusions about the observed conditions
of the property provide the rationale for the opinion of market value. The completed appraisal form
utilized, together with the required exhibits, constitutes the reporting instrument to HUD for FHA-
insured mortgages.
The FHA Appraisal is made Under the following conditions
A. “As Is” 1. There is/are no repair(s), alteration(s) or inspection conditions
noted by the appraiser, or
2. Establishing the “as is” value for a regular 203(k), or
3. The property is being recommended for rejection
B. “Subject to Completion per
Plans and Specifications”
1. Proposed Construction where construction has not started, or
2. Under Construction but not yet complete (less than 90%), or
3. Regular 203(k)
C. “Subject to the following
Repairs or Alterations”
1. Repair or Alteration Condition(s) noted by the appraiser, or
2. Streamline 203K, or
3. Under Construction, more than 90% complete with only minor
finish work remaining (buyer preference items i.e., floor
coverings, appliances, fixtures, landscaping, etc.). This
eliminates the need for construction exhibits.
D. “Subject to the following
Required Inspection”
1. Required Inspection(s) noted by the appraiser
Page 2
4150.2
1/06
D- 2
FHA Quick Tips
Minimum Property Requirements (MPR) and Minimum Property Standards (MPS)
For new construction to be eligible for FHA financing, it must comply with HUD’s Minimum Property
Standards (including 24 CFR 200.926d). Existing construction must comply with HUD’s
Minimum Property Requirements (HUD Handbook 4905.1). .
In the performance of an FHA appraisal, the appraiser must denote any deficiency in the appropriate
section(s) (site issues in the site section, improvement issues in the improvements section) of the
appraisal report. The appraiser is to note those repairs necessary to make the property comply with
FHA’s Minimum Property Requirements (MPR) or Minimum Property Standards (MPS) together with
the estimated cost to cure. The lender will determine which repairs for existing properties must be made
for the property to be eligible for FHA-insured financing.
Cosmetic repairs are not required; however, they are to be considered in the overall condition rating and
valuation of the property. Examples of cosmetic repairs would include surface treatments, beautification
or adornment not required for the preservation of the property. For example, generally, worn floor
finishes or carpeting, holes in window screens, or a small crack in a windowpane are examples of
deferred maintenance that do not rise to the level of a required repair but must be reported by the
appraiser.
The physical condition of existing building improvements is examined at the time of the appraisal to
determine whether repairs, alterations or inspections are necessary - essential to eliminate conditions
threatening the continued physical security of the property.
Required repairs will be limited to necessary requirements to:
• protect the health and safety of the occupants (Safety)
• protect the security of the property (Security)
• correct physical deficiencies or conditions affecting structural integrity (Soundness)
A property with defective conditions is unacceptable until the defects or conditions have been remedied
and the probability of further damage eliminated. Defective conditions include:
• defective construction
• other readily observable conditions that impair the safety, sanitation or structural soundness of the
dwelling
Typical conditions that would require further inspection or testing by qualified individuals or entities:
• infestation – evidence of termites
• inoperative or inadequate plumbing, heating or electrical systems
• structural failure in framing members
• leaking or worn-out roofs
• cracked masonry or foundation damage
• drainage problems
Appraisers are reminded not to recommend inspections only as a means of limiting liability. The reason
or indication of a particular problem must be given when requiring an inspection of any mechanical
system, structural system, etc.
Page 3
4150.2
1/06
D- 3
These guidelines are provided to assist in the examination of the property. To perform this analysis, the
appraiser must have full access to all property improvements.
If unable to visually evaluate the improvements in their entirety, contact the lender and reschedule a
time when a complete visual inspection can be performed. This includes access to the crawl space and
attic. The appraiser is not required to disturb insulation, move personal items, furniture, equipment, plant
life, soil, snow, ice or debris that obstructs access or visibility.
An inspection done in accordance with these guidelines is visual and is not technically exhaustive.
These guidelines are applicable to buildings with four or less dwellings units and their related property
improvements.
Unacceptable Locations
FHA guidelines require that a site be rejected if the property being appraised is subject to hazards,
environmental contaminants, noxious odors, offensive sights or excessive noises to the point of
endangering the physical improvements or affecting the livability of the property, its marketability, or
the health and safety of its occupants. Rejection may also be appropriate if the future economic life of
the property is shortened by obvious and compelling pressure to a higher use, making a long-term
mortgage impractical.
If the condition is clearly a health and safety violation, contact the lender for further instructions before
completing the appraisal. The lender must clear the condition and may require an inspection or reject
the property. If there is any doubt as to the severity, report the condition and submit the completed
report. For those conditions that cannot be repaired, such as site factors, the appraised value is based
upon the existing conditions.
Site Hazards And Nuisances
The appraiser must note and comment on all hazards and nuisances affecting the subject property that
may endanger the health and safety of the occupants and/or the structural integrity or marketability of
the property, including: subsidence, operating and abandoned oil and gas wells, abandoned wells, slush
pits, heavy traffic, airport noise and hazards, runway clear zones/clear zones, proximity to high pressure
gas, liquid petroleum pipelines or other volatile and explosive products, residential structures located
within the fall distance of a high-voltage transmission line, radio/TV transmission tower, etc., excessive
hazard from smoke, fumes, odors, and stationary storage tanks containing flammable or explosive
material.
If hazards or nuisances are observed, the appraiser must describe the condition(s) and make a
requirement for repair and/or for further inspection, and prepare the appraisal “subject to repairs” and/or
“subject to inspection” in the site section of the report. Supporting documentation provided by the
appraiser may include extra photos or copies of site studies or analyses, property reports, surveys or plot
plans, etc.
Any and all references to Valuation Condition items addressed in Chapters 2 and 3 are to be addressed
in the appropriate section of the applicable appraisal reporting form. For example, Chapter 2, Sec. 2-2-E,
Slush Pits, instructs: “If there is any readily observable evidence of slush pits, mark the "yes" column in
VC-1”. The new protocol will require the appraiser to address this condition in the site section of the
appraisal report and note that the property may not be eligible for FHA financing referencing the
information contained in chapter 2; otherwise, the guidance provided by chapters 2 and 3 remains in
effect.
Page 4
4150.2
1/06
D- 4
Soil Contamination
Check readily observable evidence of hazardous substances in the soil. Conditions that could indicate
soil contamination include pools of liquid, pits, ponds, lagoons, stressed vegetation, stained soils or
pavement, drums or odors. If any of these conditions exist further analysis or testing is required.
Note the proximity to dumps, landfills, industrial sites or other sites that could contain hazardous wastes.
If there is any readily observable surface evidence of leakage from an underground storage tank, further
analysis or testing is required. If there is readily observable evidence of on-site contamination, make a
requirement for further inspection in the site section of the report.
Grading and Drainage
Check for readily observable evidence of grading and drainage problems. Proper drainage control
measures may include gutters and downspouts or appropriate grading or landscaping to divert the flow
of water away from the foundation. If the grading does not provide positive drainage from the
improvements, make a repair requirement. Note any readily observable evidence of standing water near
the property that indicates improper drainage. If the standing water is problematic, make a repair
requirement in the site section of the report.
Individual Water Supply and Sewage Systems
Identify the type of utilities in the site section of the appraisal report. When water and sewer are
private, well and septic testing is to be governed by state or local requirements; however, the appraiser
must note any readily observable deficiencies regarding the well or septic system. The appraiser is also
required to report on the availability of connection to public and/or community water/sewer systems.
The lender is responsible for the determination of the feasibility for requiring connection.
Wood Destroying Insects/Organisms
Report any evidence of infestation in the “improvements section” of the appraisal report under
“foundation” by simply marking the evidence of infestation box.
Private Road Access and Maintenance
Address private road access in site area under “off-site improvements”. Private streets must be
protected by permanent recorded easements or be owned and maintained by a HOA. Shared driveways
must also meet these requirements.
Each property must have vehicular or pedestrian access. If the property is inaccessible by foot or by
vehicle, note this deficiency. FHA defines all-weather surface as a road surface over which emergency
vehicles can pass in all types of weather. If the property is not provided with an all-weather surface,
note the absence of such in the appraisal..
Structural Conditions
Appraiser must answer yes/no question on the appraisal addressing physical deficiencies affecting
structural integrity. If answered “yes”, provide an explanation addressing the nature of the deficiency
and recommend repairs, alterations or required inspections, in the improvements section under physical
deficiencies/adverse conditions.
Foundation
Report any evidence of dampness or settlement by noting such under the foundation section of
improvements description.
Page 5
4150.2
1/06
D- 5
Describe the nature of the deficiency and recommend repairs, alterations or required inspections, if any,
in the improvements section under physical deficiencies/adverse conditions.
Roofing
Identify roofing material type, and the condition observed, in the improvements section of the report.
The nature and degree of any noted deficiency will determine whether the appraiser addresses the
deficiency in the narrative comments area of the report under “condition of the property”, or “physical
deficiencies” affecting livability or structural soundness.
Mechanical Systems
Report on the condition of the improvements, which includes mechanical systems. The nature and
degree of any noted deficiency will determine whether to address the deficiency in the narrative
comments area of the report under “condition of the property”, or “physical deficiencies” affecting
livability or structural soundness.
Check mechanical, plumbing and electrical systems in the subject property to ensure that they are in
proper working order. This examination entails turning on the applicable systems and observing their
performance. If any conditions exist that would affect the health or safety of the occupants, condition
the appraisal on the repair or alteration of the condition” and/or a “required inspection.” The following
is not an all-inclusive list, but a listing of the more common readily observable property deficiencies.
Electrical System
• Examine the electrical system to ensure that there is no visible frayed wiring, or exposed wires in
living areas and note if the amperage appears adequate for the property.
• Operate a representative number of lighting fixtures, switches and receptacles inside the house,
garage and on the exterior walls and note any deficiencies. If the appliances present at the time
of the inspection do not appear to be reasonable (undersized), determine if there is adequate
amperage to run “standard” appliances, as per local code.
• The appraiser is not required to insert any tool, probe or testing device inside the panels or to
dismantle any electrical device or control.
Plumbing System
• Flush the toilets and turn on a representative number of faucets to determine that the plumbing
system is intact, that it does not emit foul odors, that faucets function appropriately, that both
cold and hot water run and that there is no readily observable evidence of leaks or structural
damage under fixtures.
• Turn on several cold water faucets in the house to check water pressure and flow. Flushing a
toilet at the same time will also reveal any weaknesses in water pressure.
• If the property has a septic system, examine it for any signs of failure or surface evidence of
malfunction.
Other Health and Safety Deficiencies
Address all health and safety issues, physical deficiencies or adverse conditions that affect the livability,
soundness or structural integrity of the property. The nature and degree of any health and/or safety
issues will determine whether to address said deficiency in the narrative comments area of the report
under “condition of the property”, or “physical deficiencies” affecting livability or structural
soundness.
Appendix D: Valuation Protocol: summary, contents and background
This guide helps you understand the scope of Appendix D: Valuation Protocol before or alongside reading the original document. It is based on the catalogue record, credited creator, source, classification and topics shown on this page. It does not replace the original work and does not invent claims about passages that Doxxly cannot verify.
Summary and overview
Appendix D: Valuation Protocol is a 139-page documentcredited to Umar X. Sandford. Appendix D of document 4150.2, marked 1/06, provides valuation and reporting protocols for appraisals supporting FHA-insured mortgages. It addresses minimum property requirements and standards, property inspections, repairs, environmental and safety hazards, comparable selection, appraiser responsibilities, certifications, and required exhibits. Detailed field-by-field instructions cover the Uniform Residential Appraisal Report (Fannie Mae Form 1004) and Manufactured Home Appraisal Report (Form 1004C), including property identification, neighborhood and site analysis, improvements, valuation approaches, and reconciliation. The supplied text ends partway through the manufactured-home reconciliation instructions. It appears in the Law & Legal Studies collection, which groups it with other material that readers may use for comparison and further study.
The item can be approached in several ways. A reader looking for a quick orientation can begin with the free five-page preview, inspect the page structure and use the metadata to judge relevance. Someone undertaking deeper research can work through the complete file, search its indexed text, record useful page references and compare its treatment of FHA appraisals, Valuation protocol, Residential real estate, Manufactured housing, Minimum property requirements, Property inspections, Appraisal reporting, Comparable sales, Cost approach, Mortgage insurance with the related resources linked below.
Rather than reducing the work to a single claim, this page treats it as a source that should be read in context. The title, creator, publication source, licence and format all help explain what kind of evidence it may offer. Readers should distinguish the original author's statements from Doxxly's catalogue description, and should cite the original edition when using the material in academic, professional or published work.
Key topics and reader takeaways
The catalogue connects this document with FHA appraisals, Valuation protocol, Residential real estate, Manufactured housing, Minimum property requirements, Property inspections, Appraisal reporting, Comparable sales, Cost approach, Mortgage insurance. These terms offer practical entry points rather than a substitute for close reading. Start by identifying the definitions, examples, arguments, tables or visual explanations attached to each topic. Then note where the creator draws connections, makes distinctions or moves from background material to a conclusion, recommendation, calculation or narrative development.
A useful reading method is to separate description from interpretation. First record what the item actually presents: names, headings, figures, formulas, quotations or stated propositions. Next consider why those details matter within the whole work. Finally compare them with another source from the same subject area. This process helps turn a long digital file into evidence that can be evaluated rather than merely skimmed.
Table of contents and reading guide
The following is an editorial content guide based on the verified catalogue topics. It is not represented as the original author's formal table of contents. Use it to organise notes while moving through the 139 pages in the player.
Part 1
FHA appraisals
Use this section of the reading guide to identify how FHA appraisals appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
Part 2
Valuation protocol
Use this section of the reading guide to identify how Valuation protocol appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
Part 3
Residential real estate
Use this section of the reading guide to identify how Residential real estate appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
Part 4
Manufactured housing
Use this section of the reading guide to identify how Manufactured housing appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
Part 5
Minimum property requirements
Use this section of the reading guide to identify how Minimum property requirements appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
Part 6
Property inspections
Use this section of the reading guide to identify how Property inspections appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
Part 7
Appraisal reporting
Use this section of the reading guide to identify how Appraisal reporting appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
Part 8
Comparable sales
Use this section of the reading guide to identify how Comparable sales appears in Appendix D: Valuation Protocol, note important terms, and connect the subject to the wider purpose of the work.
When a heading in the original differs from this guide, follow the original heading in your citation. Page numbers can also vary between editions. Doxxly's direct page field is useful for navigation, but formal references should include the title, creator, source and edition details available in the file itself.
About Umar X. Sandford
Doxxly credits Umar X. Sandford as the author or creator of Appendix D: Valuation Protocol. This page does not add an unverified biography, job title or institutional affiliation. The attribution is preserved so readers can distinguish the creator from the hosting library and follow the original record when an external author link is available.
Author context matters because a work reflects a particular purpose, audience and point of view. Before relying on the material, consider what the creator set out to explain, when the source was produced and whether later research or revised guidance should also be consulted. For literature and philosophy, compare translations and editions; for technical material, check whether a newer version has superseded the one shown here.
About the source organisation
The recorded source for this item is hud.gov. Doxxly provides access and discovery tools but does not claim to be the original publisher unless explicitly stated. Source links, creator attribution and the recorded Publicly available file collected for editorial review licence are displayed to help readers assess provenance and permitted use.
Provenance is especially important for reports, standards, presentations and working spreadsheets. Check the original source for amendments, supporting files and current policy. A trustworthy research workflow keeps the source URL with any notes or downloaded copy, verifies important figures against the original, and avoids treating an archived document as automatically current.
Begin with the title and opening pages, then use the guide above to decide whether to read sequentially or move to a particular topic. The Doxxly player provides previous and next navigation, a direct page field, zoom steps, fit-to-width and fit-to-page modes, rotation and fullscreen. These controls are useful when a page contains small type, a wide table, an image, a scanned layout or a dense sequence of notes.
The first five pages are open to every visitor. A plan unlocks the complete item and full-document search. Search is best used for distinctive names, technical terms or short phrases; broad words can produce too many possible contexts. When you find a useful passage, read the surrounding pages so that a sentence, chart or formula is not separated from its explanation.
If downloading is enabled, members can obtain the original PDF file. Keep the original format when formulas, slide sequencing, pagination or layout carries meaning. Respect the Publicly available file collected for editorial review terms displayed on this page, and use the rights-report link if you believe the attribution or availability needs review.
Research questions to consider
As you read Appendix D: Valuation Protocol, ask which audience the creator addresses, what problem or idea organises the work, what evidence is presented, and which assumptions remain unstated. Note whether important terms are defined consistently and whether examples represent a broader pattern or a narrow case. For quantitative material, record units, time periods, formulas and data sources. For interpretive material, separate the creator's language from your own summary.
A second set of questions concerns relevance today. Which parts remain durable, which depend on their historical or institutional setting, and what would need confirmation from a newer source? Following the tags and the Law & Legal Studies collection can reveal useful comparisons. Agreement between sources can strengthen confidence, while disagreement can point to changing definitions, methods, evidence or priorities.
Finally, decide what you need from the item: background knowledge, a quotation, a worked example, a model, a visual explanation or a starting bibliography. That purpose should guide the depth of reading and the notes you keep. Doxxly helps locate and navigate the source; careful interpretation remains the reader's responsibility.