Page 1 of 40Free preview · 1–5

About this document

Product data sheet PS-00603, Rev. AK, dated August 2023, covering Micro Motion F-Series Coriolis flow and density meters. Describes measurement principles, liquid and gas performance, flow rates, pressure and temperature limits, two-phase flow considerations, diagnostics, certifications, transmitter compatibility, materials, connections, and dimensions. Includes model-specific ordering codes, calibration options, and available certificates, tests, and services. Premium liquid mass flow accuracy of ±0.05% and density accuracy of ±0.5 kg/m³ are available on selected models.

Free preview text

The first 5 pages, shown as text so search engines and readers can find this document.

Page 1

Product Data Sheet PS-00603, Rev AK August 2023 Micro Motion™ F-Series Flow and Density Meters VIEW PRODUCT > High accuracy real world performance ■ Best-in-class performance on liquid mass flow, volume flow, and density measurements in a compact design (up to ±0.05 percent liquid mass accuracy and up to ±0.5 kg/m3 liquid density accuracy) ■ Rugged design minimizing process, mounting, and environmental effects Best fit-for-application ■ Cleanable, self-draining design for critical process control service ■ Compact design enables installation flexibility ■ Broad range of input/output offerings including HART®, Profibus®-DP, FOUNDATION™ Fieldbus, 4-20 mA, and wireless capabilities Exceptional reliability and safety ■ No moving parts to wear or replace minimizes maintenance for long-term reliability ■ 316L stainless steel and nickel alloy C22 wetted parts construction for compatibility with most fluids ■ Robust sensor design

Page 2

Micro Motion F-Series flow and density meters Micro Motion F-Series meters deliver superb measurement with exceptional flow and density performance as well as outstanding reliability for use in critical process control environments. Optimal flow and density fit for critical process applications ■ High performance rugged measurement in a compact drainable design that maximizes process up time ■ Low frequency, high sensitivity fit-and-forget meter provides robust measurements even under demanding process conditions ■ Multiple line sizes provide an ideal platform for batching, distribution, allocation, and intra-plant measurement applications Smart Meter Verification™: advanced diagnostics for your entire system ■ Ordered as standard with the option to license flow range detection and other advanced meter health diagnostics ■ Runs comprehensive tests that can be scheduled, run locally, or from the control room to provide confidence in your meter functionality and performance ■ Verifies that your meter performs as well as the day it was installed, giving you assurance in less than 90 seconds ■ Saves significant expenditure by reducing labor and extending or eliminating calibration intervals without interrupting the process Industry-leading capabilities that unleash your process potential ■ Available with the most extensive offering of transmitter and mounting options for maximum compatibility with your system ■ State of the art, ISO/IEC 17025 compliant calibration stands achieving ±0.014 percent uncertainty drive best in class measurement accuracy ■ The most comprehensive communication protocol offering in the industry including Smart Wireless ■ True multi-variable technology measures necessary flow and density process variables simultaneously Widest range of installation and process condition flexibility ■ Featuring a low pressure drop, low weight design that reduces installation and commissioning costs ■ Unmatched MVD™ transmitter technology with digital signal processing (DSP) delivers the fastest response rates, enabling accurate batch and process measurement ■ Design flexibility enables operation at high temperature up to 662 °F (350 °C) or high pressure up to 6,237 psig (430 barg) to solve your toughest measurement challenges Access information when you need it with asset tags Newly shipped devices include a unique QR code asset tag that enables you to access serialized information directly from the device. With this capability, you can: ■ Access device drawings, diagrams, technical documentation, and troubleshooting information in your MyEmerson account ■ Improve mean time to repair and maintain efficiency ■ Ensure confidence that you have located the correct device ■ Eliminate the time-consuming process of locating and transcribing nameplates to view asset information Micro Motion F-Series August 2023 2 Emerson.com

Page 3

Measurement principles As a practical application of the Coriolis effect, the Coriolis mass flow meter operating principle involves inducing a vibration of the flow tube through which the fluid passes. The vibration, though it is not completely circular, provides the rotating reference frame which gives rise to the Coriolis effect. While specific methods vary according to the design of the flow meter, sensors monitor and analyze changes in frequency, phase shift, and amplitude of the vibrating flow tubes. The changes observed represent the mass flow rate and density of the fluid. Mass and volume flow measurement The measuring tubes are forced to oscillate producing a sine wave. At zero flow, the two tubes vibrate in phase with each other. When flow is introduced, the Coriolis forces cause the tubes to twist resulting in a phase shift. The time difference between the waves is measured and is directly proportional to the mass flow rate. Volume flow rate is calculated from mass flow rate and the density measurement. Watch this video to learn more about how a Coriolis flow meter measures mass flow and density (click the link and select View Videos): https://www.emerson.com/en-us/automation/measurement-instrumentation/flow-measurement/ coriolis-flow-meters. A. Inlet pick off displacement B. No flow C. Outlet pick off displacement D. Time E. Inlet pick off displacement F. With flow G. Outlet pick off displacement H. Time difference I. Time Density measurement The measuring tubes are vibrated at their natural frequency. A change in the mass of the fluid contained inside the tubes causes a corresponding change to the tube's natural frequency. The frequency change of the tube is used to calculate density. August 2023 Micro Motion F-Series Micro Motion F-Series 3

Page 4

Temperature measurement Temperature is a measured variable that is available as an output. The temperature is also used internally in the sensor to compensate for temperature influences on Young’s Modulus of Elasticity. Meter characteristics ■ Measurement accuracy is a function of fluid mass flow rate independent of operating temperature, pressure, or composition. However, pressure drop through the sensor is dependent upon operating temperature, pressure, and fluid composition. ■ Specifications and capabilities vary by model and certain models may have fewer available options. For detailed information regarding performance and capabilities, either contact customer service or visit www.emerson.com. ■ The letter at the end of the base model code (for example F100S) represents the wetted part material and/or application designation: S Stainless steel H Nickel alloy C22 P High pressure A High temperature 316L stainless steel B High temperature nickel alloy C22 Detailed information about the complete product model codes are described in Ordering information. Performance specifications Reference operating conditions For determining the performance capabilities of our meters, the following conditions were observed / utilized: ■ Water at 68 °F (20 °C) to 77 °F (25 °C) and 14.5 psig (1 barg) to 29 psig (2 barg), installed in a tubes-down orientation ■ Air and natural gas at 68 °F (20 °C) to 77 °F (25 °C) and 500 psig (34 barg) to 1,450 psig (100 barg), installed in a tubes-up orientation ■ Accuracy based on industry leading accredited calibration standards according to ISO 17025/IEC 17025 ■ A density range up to 3,000 kg/m³ (3 g/cm³) on all models Accuracy and repeatability Accuracy and repeatability on liquids and slurries Performance specifications Premium(1) Enhanced(1) Intermediate Basic Mass and volume flow(2) ±0.05% ±0.1% ±0.15% ±0.2% Mass and volume repeatability 0.025% 0.05% 0.075% 0.10% Density accuracy ±0.5 kg/m³ (±0.0005 g/cm³) ±1 kg/m³ (±0.001 g/cm³) ±2 kg/m³ (±0.002 g/ cm³) Density repeatability 0.2 kg/m³ (0.0002 g/ cm³) 0.5 kg/m³ (0.0005 g/cm³) 1 kg/m³ (0.001 g/ cm³) Temperature accuracy ±1 °C ±0.5% of reading Micro Motion F-Series August 2023 4 Emerson.com

Page 5

Performance specifications Premium(1) Enhanced(1) Intermediate Basic Temperature repeatability 0.2 °C (1) Not available on all models. (2) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. Accuracy and repeatability on gases Performance specification F050S/H, F100S/H, F150S, F200S/H, F300S/H, and F400S F025S/H, all high temperature (A/B), and high pressure (P) models Mass flow accuracy(1) ±0.35% of rate ±0.5% of rate Mass flow repeatability(1) 0.25% of rate 0.25% of rate Temperature accuracy ±1 °C ±0.5% of reading Temperature repeatability 0.2 °C (1) Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. Warranty Warranty options on all F-Series models The warranty period is generally initiated from the day of shipment. For warranty details, see the Terms and Conditions included with the standard product quote. Base model Included as standard Included with start-up service Available for purchase F025-400 (S/H/A/B/P) 18 months 36 months > 36 months (customizable length) Liquid flow rates Nominal flow rate Emerson has adopted the term nominal flow rate, which is the flow rate at which water at reference conditions causes approximately 14.5 psig (1 barg) of pressure drop across the meter. Table 1 shows mass flow rates using 316L stainless steel (S/A), nickel alloy C22 (H/B), and high pressure (P). Table 1: Mass flow rates for all models Model Nominal line size Nominal flow rate Maximum flow rate lb/min kg/h lb/min kg/h F025 0.25 in (DN6) 50 1,366 100 2,720 F050P 0.5 in (DN15) 84 2,287 168 4,570 F050S/H/A/B 0.5 in (DN15) 155 4,226 300 8,160 F100P 1 in (DN25) 400 11,000 800 22,000 F100S/H/A/B 1 in (DN25) 717 19,500 1,200 32,700 F150S 1.5 in (DN40) 1,102 29,992 2,000 54,431 F200 2 in (DN50) 2,190 59,500 3,200 87,100 F300 3 in (DN80) 4,900 133,000 8,740 238,000 F400 4 in (DN100) 12,000 327,000 16,000 436,000 August 2023 Micro Motion F-Series Micro Motion F-Series 5

Tags

Doxxly editorial guide

Micro Motion™ F-Series Flow and Density Meters: summary, contents and background

This guide helps you understand the scope of Micro Motion™ F-Series Flow and Density Meters before or alongside reading the original document. It is based on the catalogue record, credited creator, source, classification and topics shown on this page. It does not replace the original work and does not invent claims about passages that Doxxly cannot verify.

Summary and overview

Micro Motion™ F-Series Flow and Density Meters is a 40-page documentcredited to Kaya M. Alder. Product data sheet PS-00603, Rev. AK, dated August 2023, covering Micro Motion F-Series Coriolis flow and density meters. Describes measurement principles, liquid and gas performance, flow rates, pressure and temperature limits, two-phase flow considerations, diagnostics, certifications, transmitter compatibility, materials, connections, and dimensions. Includes model-specific ordering codes, calibration options, and available certificates, tests, and services. Premium liquid mass flow accuracy of ±0.05% and density accuracy of ±0.5 kg/m³ are available on selected models. It appears in the Science & Engineering collection, which groups it with other material that readers may use for comparison and further study.

The item can be approached in several ways. A reader looking for a quick orientation can begin with the free five-page preview, inspect the page structure and use the metadata to judge relevance. Someone undertaking deeper research can work through the complete file, search its indexed text, record useful page references and compare its treatment of Product data sheet, Micro Motion, Emerson, F-Series, Coriolis flow meters, Density measurement, Process instrumentation, Smart Meter Verification, Technical specifications, Ordering information with the related resources linked below.

Rather than reducing the work to a single claim, this page treats it as a source that should be read in context. The title, creator, publication source, licence and format all help explain what kind of evidence it may offer. Readers should distinguish the original author's statements from Doxxly's catalogue description, and should cite the original edition when using the material in academic, professional or published work.

Key topics and reader takeaways

The catalogue connects this document with Product data sheet, Micro Motion, Emerson, F-Series, Coriolis flow meters, Density measurement, Process instrumentation, Smart Meter Verification, Technical specifications, Ordering information. These terms offer practical entry points rather than a substitute for close reading. Start by identifying the definitions, examples, arguments, tables or visual explanations attached to each topic. Then note where the creator draws connections, makes distinctions or moves from background material to a conclusion, recommendation, calculation or narrative development.

A useful reading method is to separate description from interpretation. First record what the item actually presents: names, headings, figures, formulas, quotations or stated propositions. Next consider why those details matter within the whole work. Finally compare them with another source from the same subject area. This process helps turn a long digital file into evidence that can be evaluated rather than merely skimmed.

Table of contents and reading guide

The following is an editorial content guide based on the verified catalogue topics. It is not represented as the original author's formal table of contents. Use it to organise notes while moving through the 40 pages in the player.

  1. Part 1

    Product data sheet

    Use this section of the reading guide to identify how Product data sheet appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

  2. Part 2

    Micro Motion

    Use this section of the reading guide to identify how Micro Motion appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

  3. Part 3

    Emerson

    Use this section of the reading guide to identify how Emerson appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

  4. Part 4

    F-Series

    Use this section of the reading guide to identify how F-Series appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

  5. Part 5

    Coriolis flow meters

    Use this section of the reading guide to identify how Coriolis flow meters appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

  6. Part 6

    Density measurement

    Use this section of the reading guide to identify how Density measurement appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

  7. Part 7

    Process instrumentation

    Use this section of the reading guide to identify how Process instrumentation appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

  8. Part 8

    Smart Meter Verification

    Use this section of the reading guide to identify how Smart Meter Verification appears in Micro Motion™ F-Series Flow and Density Meters, note important terms, and connect the subject to the wider purpose of the work.

When a heading in the original differs from this guide, follow the original heading in your citation. Page numbers can also vary between editions. Doxxly's direct page field is useful for navigation, but formal references should include the title, creator, source and edition details available in the file itself.

About Kaya M. Alder

Doxxly credits Kaya M. Alder as the author or creator of Micro Motion™ F-Series Flow and Density Meters. This page does not add an unverified biography, job title or institutional affiliation. The attribution is preserved so readers can distinguish the creator from the hosting library and follow the original record when an external author link is available.

Author context matters because a work reflects a particular purpose, audience and point of view. Before relying on the material, consider what the creator set out to explain, when the source was produced and whether later research or revised guidance should also be consulted. For literature and philosophy, compare translations and editions; for technical material, check whether a newer version has superseded the one shown here.

About the source organisation

The recorded source for this item is emerson.com. Doxxly provides access and discovery tools but does not claim to be the original publisher unless explicitly stated. Source links, creator attribution and the recorded Publicly available file collected for editorial review licence are displayed to help readers assess provenance and permitted use.

Provenance is especially important for reports, standards, presentations and working spreadsheets. Check the original source for amendments, supporting files and current policy. A trustworthy research workflow keeps the source URL with any notes or downloaded copy, verifies important figures against the original, and avoids treating an archived document as automatically current.

Visit emerson.com

How to read and use this document

Begin with the title and opening pages, then use the guide above to decide whether to read sequentially or move to a particular topic. The Doxxly player provides previous and next navigation, a direct page field, zoom steps, fit-to-width and fit-to-page modes, rotation and fullscreen. These controls are useful when a page contains small type, a wide table, an image, a scanned layout or a dense sequence of notes.

The first five pages are open to every visitor. A plan unlocks the complete item and full-document search. Search is best used for distinctive names, technical terms or short phrases; broad words can produce too many possible contexts. When you find a useful passage, read the surrounding pages so that a sentence, chart or formula is not separated from its explanation.

If downloading is enabled, members can obtain the original PDF file. Keep the original format when formulas, slide sequencing, pagination or layout carries meaning. Respect the Publicly available file collected for editorial review terms displayed on this page, and use the rights-report link if you believe the attribution or availability needs review.

Research questions to consider

As you read Micro Motion™ F-Series Flow and Density Meters, ask which audience the creator addresses, what problem or idea organises the work, what evidence is presented, and which assumptions remain unstated. Note whether important terms are defined consistently and whether examples represent a broader pattern or a narrow case. For quantitative material, record units, time periods, formulas and data sources. For interpretive material, separate the creator's language from your own summary.

A second set of questions concerns relevance today. Which parts remain durable, which depend on their historical or institutional setting, and what would need confirmation from a newer source? Following the tags and the Science & Engineering collection can reveal useful comparisons. Agreement between sources can strengthen confidence, while disagreement can point to changing definitions, methods, evidence or priorities.

Finally, decide what you need from the item: background knowledge, a quotation, a worked example, a model, a visual explanation or a starting bibliography. That purpose should guide the depth of reading and the notes you keep. Doxxly helps locate and navigate the source; careful interpretation remains the reader's responsibility.

Explore more Science & Engineering resources

Frequently asked questions about Micro Motion™ F-Series Flow and Density Meters

Practical answers about reading, downloading and understanding this document on Doxxly.

More in Science & Engineering